MRS start page MRS electronic: automotive relays und automotive electronics
 
Products Controller

PROP CAN - Proportional amplifier

Description
The proportional valve controller with CAN Bus serves to regulate the flow rates of a proportional valve. It can be used for many hydraulic applications. CAN high- or low-speed (alternatively RS485) Bus can be used to communicate with further systems and offer an easy integration in existing systems.
Function
The micro controller's current control is direct proportional to the set-point 0 - 10 Volt or 0 - 20 mA. Contolling and read/write of all values by CAN Bus possible. Fluctuations in supply voltage and temperature are compensated. Thereby a constant flow rate is ensured. In order to avoid a determining of the valve, a Dither frequency (overlaid rectangle with smaller frequency) can be adjusted. For different housing please see in the chapter housing and baseplates.
Technical data

Operating voltage: 9-30 V
Quiescent current: <250 µA (stand by), 30 mA (idle)
continuous current: max. 3 A
Ingress protection: IP53

Design

PROP CAN - Proportional amplifier 1PROP CAN - Proportional amplifier 1PROP CAN - Proportional amplifier 2PROP CAN - Proportional amplifier 2PROP CAN - Proportional amplifier 3PROP CAN - Proportional amplifier 3PROP CAN - Proportional amplifier 4PROP CAN - Proportional amplifier 4PROP CAN - Proportional amplifier 5PROP CAN - Proportional amplifier 5
Connection diagram
PROP CAN - Proportional amplifier 1PROP CAN - Proportional amplifier 1 PROP CAN - Proportional amplifier 2PROP CAN - Proportional amplifier 2 PROP CAN - Proportional amplifier 3PROP CAN - Proportional amplifier 3 PROP CAN - Proportional amplifier 4PROP CAN - Proportional amplifier 4 PROP CAN - Proportional amplifier 5PROP CAN - Proportional amplifier 5 PROP CAN - Proportional amplifier 6PROP CAN - Proportional amplifier 6
Download
Any more questions?
Call +49 741/2807-12 or
sales@kfz-relais.com
Click on the "PDF-button" to see our catalog completely.
Download

Order Table
Ordering Text
Style
Housing
Ordering Number
Proportional amplifier CAN 9-30 V Desired voltage/ Current with CAN bus S1/G2/E 1.108.310.00E

Design may be subject of change - no warranty can be given for this information.
 