Description
Time relay switch-off delay adjustable offer a time adjustment via poti within the defined time period.
One can choose betweeen 5 time spans (see table below). Different time periods can be defined on demand.
Please specify the required switch-off delay time (time period) in your order.
Application Examples
Fan switch-off delay
Lights switch-off delay
Function All diagrams: The supply voltage is applied to terminal 30/87z. If the signal voltage is applied to terminal 15, the relay switches on. Is signal removed the relay switches off after the delay time has elapsed.
Diagram S3: Due to the integrated decoupling diodes, the relay needs no quiescent current after it has dropped out.
For different housing please see in the chapter housing and baseplates.
Function Diagram Technical data
operating temp.: -40 °C to 85 °C
continuous current: 10 A/15 A (Ö/S)
Time tolerance: ± 1 %
Ingress protection: IP53 (with poti cover)
Quiescent current: 250 µA
EMC: 95/54 EG; DIN 40839
e1 approval-no.: 023218
Design Connection diagram additional ordering data Time interval | Time indication | | xx = 01: | 0.5 -5 sec.
| | xx = 02: | 1 - 30 sec.
|
|---|
| xx = 03: | 0.5 - 60 sec.
|
|---|
| xx = 04: | 0.5 - 900 sec.
|
|---|
| xx = 05: | 0,5 - 4000 sec. |
|