Description
This relay can be used to switch-off a consumers time delayed . Please specify the required switch-off delay time in your order.
Application Examples
Defrost
Delayed switching off of lights
Follow-up control
Follow-up control
Function All diagrams: To terminal 30/87z supply voltage is applied. As soon as signal voltage is applied to terminal 15 the relay switches on immediatly. If signal voltage is removed from terminal 15 the relay switches off after the defined delay time.
Diagram S2: The contacts are seperated from the trigger, therefore they can be used in combinations. Regarding version S2 the relay contact is completely potential-free thus it is able to switch alternating voltage.
Diagram S3: Due to the diode the relay needs no quiescent current after it has switched-off. Variant S3 only 10/15A (O/C)
For different housing please see in the chapter housing and baseplates.
Function Diagram Technical data
operating temp.: -40 °C to 85 °C
continuous current: 30 A (S3 = 10/15 A)
max. switching volt.: 75 VDC
max. switching curr.: 60 A
max. switch-on current: 100 A
Quiescent current: 1 mA
EMC: 2006/28/EG DIN 40839
Delay time: custom defined
Ingress protection: IP53
IP65: on customerīs request
S1+S2: e1 approval-no.: 03 5388
S3: e1 approval-no.: 02 3218
Design Connection diagram |