Description
Time relay switch-on delay adjustable offer a time adjustment via poti within the given time period. One can choose betweeen 5 time spans (see table below). Different time periods can be defined on demand. Please specify the required switch-on delay time (time period) in your order .
Application Examples
Air conditioning switch-on delay
Compressors switch-on delay
Function All diagrams: The supply voltage is applied to terminal 30/87z. If the signal voltage is applied to terminal 15 the relay switches after the delay time has elapsed. If voltage is removed the relay switches off immediatly.
Diagram S2:The contacts are seperated from the trigger, therefore they can be used in combinations.
For different housing please see in the chapter housing and baseplates.
Function Diagram Technical data
operating temp.: -40 °C to 85 °C
continuous current: 10 A/15 A (Ö/S)
Time tolerance: ± 1 %
Ingress protection: IP53 (with poti cover)
Quiescent current: 250 µA
EMC: 95/54 EG; DIN 40839
e1 approval-no.: 023218
Design Connection diagram additional ordering data Time interval | Time indication | | xx = 01: | 0.5 - 5 sec.
| | xx = 02: | 1 - 30 sec.
|
|---|
| xx = 03: | 0.5 - 60 sec.
|
|---|
| xx = 04: | 0.5 - 900 sec.
|
|---|
| xx = 05: | 0,5 - 4000 sec. |
|